ISSUED: 04-08-08 SHEET #: 055-9094-2 06-06-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
5 of 16
Make sure that the mounting holes are on the stud centerline. Drill six 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep.
Fasten two #14 x 2.5" wood screws (Q) into top mounting holes leaving a .25" of exposed thread as shown. Hook
wall mount assembly (A) onto #14 x 2.5" wood screws (Q) as shown in fig. 2.1.
Fasten four #14 x 2.5" wood screws (Q) into wall mount assembly (A) as shown in fig. 2.2. Make sure that the wall
mount assembly (A) is level, tighten all six #14 x 2.5" wood screws (Q).
Skip to step 3.
Installation to Wood Stud Wall
Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
WARNING
2
fig. 2.1
fig. 2.2
CARRIAGE
CARRIAGE
.25"
A
Q
Q
A
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 ... 15 16

Commentaires sur ces manuels

Pas de commentaire